Skip to Content

Vessel-mounted ADCP and tidal height surveys in Cuan Sound, Scotland

2017
12 November 2017 by
Vessel-mounted ADCP and tidal height surveys in Cuan Sound, Scotland
DYNAMOCEAN, Eloi Droniou

Client

CUAN ISLAND COUNCIL

Date

2017

Location

Cuan Sound, Scotland, United Kingdom

Budget

c. €16k

Needs

The Isle of Luing community was exploring a tidal energy project in Cuan Sound, the narrow channel between the islands of Luing and Seil on the west coast of Scotland. Before going further, the islanders needed measured data on how tidal currents vary across and along the channel, and a first estimate of the energy that could be extracted.

Objectives

01

Map tidal currents across and along Cuan Sound at spring and neap tides

02

Relate the flow to the water levels at both ends of the channel

03

Identify the most promising area for turbines and give a first estimate of the energy potential

Missions

01 Definition of the survey tracks with the islanders and Aquatera
02 Deployment and recovery of two tide gauges at both ends of the sound for more than 35 days
03 Vessel-mounted ADCP surveys: a coarse spring-tide session, then detailed sessions at spring and neap tides
04 Quality control, interpolated current charts, discharge calculation and harmonic analysis of water levels
05 Estimate of the extractable power and annual energy production, with recommendations

Resources deployed

Teledyne RDI Monitor 600 kHz ADCP on a pole, with a directional GPS, on a local vessel

Two NKE SP2T pressure and temperature recorders, one 1-minute burst every 15 minutes

Detailed transects 75 m apart, combined with 2 m resolution UKHO bathymetry

Processing with VmDAS, WinADCP and DynamOcean's in-house Matlab tools

Results

35

days of water level records

75 m

spacing between detailed transects

4 MW

theoretical mean extractable power

2 MW

technical mean power estimate

  • Very good quality current data, with current peaks occurring at the same time as peaks in the water level difference across the sound
  • Best location identified in the narrowest and shallowest part of the channel, favourable to both ebb and flood
  • Area around Cleit Rock found less promising, with a strong vertical gradient and variable current direction
  • About 4 MW of theoretical mean extractable power and 2 MW at technical level, for example six 1 MW turbines
  • Gridded current data delivered for the next steps: numerical modelling and array layout optimisation

Our added value

DynamOcean combined the tide gauge and ADCP data to show that the water level difference across the sound drives the flow, then predicted discharge and power over 20 years. This gave the community a first estimate of annual energy production from only three days of current surveys.