Client
Date
Location
Budget
Needs
The Peligre hydroelectric dam on the Artibonite, Haiti's main river, mostly supplies the capital, while nearby villages are still not connected to the grid. The Inter-American Development Bank (IDB) wanted to know whether small in-stream river turbines downstream of the dam could supplement its output or supply these rural areas directly. This required measured flow velocities and depths, and an up-to-date view of available technologies.
Objectives
Measure flow velocity and depth at the most promising sites downstream of the Peligre dam
Check the sites against viability thresholds for river hydrokinetic turbines
Estimate the installable capacity of pilot turbine farms
Recommend the further studies needed to move the project forward
Missions
Resources deployed
Teledyne RDI RiverRay ADCP in a tri-hull riverboat, coupled with a Hemisphere GNSS receiver
Rope system across the river and Bluetooth link to a shore-based laptop for real-time quality control
Acquisition and processing with WinRiver II, results integrated into a GIS
Four days of survey in early December 2013, at the start of the dry season

ADCP tri-hull boat tethered across the river for a velocity transect

View of the Artibonite River valley during the dry season
Results
5
sites surveyed
3
sites above the viability thresholds
3.5 m/s
maximum flow velocity measured
c. 90 kW
estimated installed capacity
- Three of the five sites exceed the thresholds of 2 m/s velocity and 1.5 m depth
- Fastest flows found just downstream of the Peligre and Canneau dams, with depths around 2 m
- Measurements made at the minimum dam release of 50 m³/s, so measured velocities are likely the lowest of the year
- Three pilot farms proposed with a commercially available 5 kW turbine, for about 90 kW in total and a potentially very high capacity factor
- Recommendations on long-term discharge data, numerical modelling, flood and sediment risks, and turbulence measurements
Our added value
Beyond the hydrokinetic assessment, DynamOcean identified the potential of retrofitting conventional low-head hydropower at the Canneau irrigation dam and its canal intakes, and recommended assessing this option.