Wave measurements to assess a wave attenuator on Lake Serre-Ponçon

2024
8 September 2024 by
Wave measurements to assess a wave attenuator on Lake Serre-Ponçon
DYNAMOCEAN, Eloi Droniou
Client logo: SPI-SEA

Client

SPI-SEA

Date

2024

Location

Lake Serre-Ponçon, French Alps, France

Budget

c. €5k

Needs

SPI-SEA was testing a wave attenuator on Lake Serre-Ponçon in August 2024 and needed to know how effectively it reduced the waves. This required simultaneous wave measurements upstream and downstream of the structure. SPI-SEA handled the deployment on site and asked DynamOcean to supply and configure the instruments and to process the data.

Objectives

01

Measure wave height, period and direction simultaneously upstream and downstream of the attenuator

02

Quantify the reduction in wave height across the attenuator

03

Provide processed time series in formats ready for use

Missions

01 Supply, configuration and testing of two 5-beam ADCPs for deployment depths of 10 and 12 m
02 Compass calibration with each ADCP mounted on its frame, and fitting of external battery packs
03 Definition of the valid measurement period from auxiliary data and the operations schedule
04 Wave processing in Ocean Contour, quality control and comparison of the two stations
05 Delivery of a report and data in Excel and CSV formats

Resources deployed

Two Nortek Signature 1000 ADCPs with acoustic surface tracking (AST) on the vertical beam

40 cm cells, 8 Hz sampling, 17-minute bursts every 30 minutes

Seabed frames and 540 Wh external battery packs

Ocean Contour with the MLMST wave method, combining AST and slanted-beam velocities

Ballasted Signature 1000 ADCP frame ready for deployment from the work pontoon

Ballasted Signature 1000 ADCP frame ready for deployment from the work pontoon

Nortek Signature 1000 ADCP mounted in its seabed frame

Nortek Signature 1000 ADCP mounted in its seabed frame

The wave attenuator seen from the shore under the bridge

The wave attenuator seen from the shore under the bridge

Results

2

stations, upstream and downstream

12

days of valid measurements

0.3 m

maximum Hm0 upstream

0.16 m

maximum Hm0 downstream

  • Time series of Hm0, Tp, Tm02, Tenergy, wave directions and water level at both stations
  • Short wind waves, with mean periods of about 1 s
  • Significant wave height clearly lower downstream of the attenuator than upstream throughout the test
  • All measurement intervals passed quality control in Ocean Contour
  • Results gave SPI-SEA a direct, measured indicator of the attenuator's effect

Our added value

On a glassy, windless lake the surface-tracking beam produced spurious low-frequency energy in some wave spectra. DynamOcean identified the cause and set a 0.22 Hz lower frequency limit that removed it while keeping the real sea state, so every interval passed quality control.