Skip to Content

Seabed and vessel-mounted ADCP surveys upstream of the Rance tidal barrage

2018
23 June 2019 by
Seabed and vessel-mounted ADCP surveys upstream of the Rance tidal barrage

Client

VDC Offshore (SARC, Eaux du pays de Saint-Malo)

Date

2018

Location

Rance estuary, upstream of the tidal barrage, France

Budget

c. €23k

Needs

SARC (Eaux du Pays de Saint-Malo) was laying a drinking water pipe across the Rance estuary, upstream of the tidal power plant, with VDC Offshore carrying out the marine works. Currents in this area are strong and depend on both the tide and the operation of the barrage. VDC Offshore needed measured current speeds along the pipe route to plan the laying operations safely.

Objectives

01

Map current speed and direction along the pipe route during the flood tide

02

Record currents continuously at a fixed point over several spring-neap cycles

03

Estimate the maximum currents to be expected near the seabed along the route

Missions

01 Configuration of a seabed ADCP in its gimballed frame and handover to VDC Offshore for deployment
02 Three vessel-mounted ADCP surveys along the pipe route, in February and May 2018
03 Post-processing and quality control, including heading alignment between ADCP and GNSS compass
04 Analysis of peak currents against tidal range and rate of water level change
05 Estimation of maximum currents and recommendations for the laying operations

Resources deployed

Teledyne RDI Sentinel V50 500 kHz ADCP in a 190 kg gimballed aluminium frame

10-minute ensembles (2 min at 2 Hz), 50 cm cells up to 25 m range

Pole-mounted TRDI Workhorse Sentinel 600 kHz ADCP with Hemisphere V102 GNSS compass, 8 s averages

WinADCP, VmDas and DynamOcean's in-house Matlab routines

Seabed ADCP frame on the workboat deck before deployment in the Rance estuary

Seabed ADCP frame on the workboat deck before deployment in the Rance estuary

Workhorse ADCP transducer on its pole mount for the vessel-mounted transects

Workhorse ADCP transducer on its pole mount for the vessel-mounted transects

Results

3

vessel-mounted ADCP surveys

2.4 m/s

maximum current measured near the surface

0.92

correlation between peak flood current and rate of water level rise

  • Current maps, time series and vertical profiles along the pipe route for each survey
  • Strongest currents found at one point of the route, reaching 2.4 m/s near the surface during the May survey
  • Peak near-bed flood current better correlated with the rate of water level rise (0.92) than with tidal range (0.85)
  • Maximum near-bed current along the route estimated at 2.0 m/s, including a 10 % margin, for planning
  • Practical recommendations issued for monitoring future laying operations

Our added value

As currents upstream of the barrage depend on how the plant is operated, DynamOcean related peak currents to the rate of water level rise rather than to tidal range alone. This gave a better indicator for anticipating the strongest currents during the laying window.