Client
Date
Location
Budget
Needs
Orcades Marine was running sea trials of the ELAN metocean buoy in the Pentland Firth, between Swona and South Ronaldsay, in one of the strongest tidal channels in Europe. To assess the buoy's performance in real conditions, its outputs had to be compared with independent reference measurements of current, turbulence and waves. As these data were critical to the trial, a redundant setup with two ADCPs was recommended.
Objectives
Measure currents through the water column next to the buoy during the trial
Provide real-time current data from the vessel during operations
Characterise turbulence and waves at the trial location
Supply reference datasets for comparison with the buoy outputs
Missions
Resources deployed
Teledyne RDI Sentinel V 500 kHz 5-beam ADCP on a gimbal in a seabed frame, about 65 m deep
Teledyne RDI Workhorse Monitor 600 kHz ADCP on the vessel's instrumentation pole, with VmDas
Interleaved 1 Hz pings: 1.5 m cells for currents and 0.5 m cells for surface tracking
Local work vessel from Orkney and DynamOcean's in-house quality-control and analysis tools
Results
5
days of seabed measurements
3.5 m/s
maximum flood current in the top 10 m
10 %
turbulence intensity at strong flood
1.2 m
maximum significant wave height during the trial
- Good overall data quality despite strong currents and simultaneous operation of two ADCPs
- Strongly bidirectional flow, with a dominant south-going flood reaching 3.5 m/s near the surface
- Turbulence intensities up to 10 % for flood currents of 3 to 3.5 m/s, with 5 of the 6 Reynolds stresses computed
- Significant wave height between 0.2 and 1.2 m and mean period between 4.5 and 9 s during the trial
- Five-minute current data and 20-minute wave data delivered in Excel for comparison with the buoy outputs
Our added value
The vessel-mounted data were intermittent in strong currents. DynamOcean showed that the highest valid cell of the seabed ADCP closely matched the vessel measurements, so the seabed record could describe the top 10 m of the water column continuously, and removed interference between the two instruments with a phase-space filter.