Skip to Content

Current study in the Bay of Morlaix for water-quality model validation

2025 - 2026
20 July 2025 by
Current study in the Bay of Morlaix for water-quality model validation
DYNAMOCEAN, Eloi Droniou
Client logo: ACRI-IN

Client

ACRI-IN

Date

2025 - 2026

Location

Bay of Morlaix, France

Budget

c. €9k

Needs

As part of the Trégor-Léon water vulnerability profile, ACRI-IN was modelling currents in the Bay of Morlaix to study the dispersion of effluents. The model had so far only been validated against water levels at ports and tide gauges. ACRI-IN needed measured currents in the upper Penzé and Morlaix estuaries, where currents are strong and the channel cross-section varies greatly, to validate its hydrodynamics.

Objectives

01

Turn existing vessel-mounted ADCP surveys into validated current data

02

Provide depth-averaged currents along each crossing at 10 m spacing, with depth and data quality indicator

03

Supply 3D velocity sections and raw transects for comparison with the model

Missions

01 Reprocessing of 2022 vessel-mounted ADCP surveys on the Penzé and Morlaix rivers
02 Quality control with side-lobe and correlation filters, and calibration of the ADCP-GNSS heading offset
03 Gridding of each cross-section at 10 m by 1 m, with extrapolation to the surface and seabed
04 Calculation of depth-averaged currents and delivery of Excel files with a report and maps

Resources deployed

Teledyne RDI RiverPro 1200 kHz ADCP and Hemisphere dual-antenna GNSS on an inflatable survey boat

Surveys at spring tides (coefficients above 90), from 3 hours before to 3 hours after high water

DynamOcean's in-house vessel-mounted ADCP processing suite

Preparing the inflatable survey boat with its side-mounted ADCP before the 2022 campaign

Preparing the inflatable survey boat with its side-mounted ADCP before the 2022 campaign

Results

13

river cross-sections

85

transects processed

0.8 m/s

maximum current

  • Data of generally good quality on both rivers
  • Seven runs over seven sections on the Penzé and six runs over six sections on the Morlaix river, on flood and ebb
  • Maximum currents of about 0.8 m/s
  • Validated current data delivered for model comparison in a narrow, high-current zone

Our added value

By reprocessing existing vessel-mounted ADCP surveys with its own tools, DynamOcean delivered validation data within the requested one-month timeframe, without a new field campaign.